Appendix I
Set-Up Functions
Changing Display Update Rate (INT Mode)
The int key is factory preset to provide a rapid display update (short integration time)
for pouring liquids to a target weight. The use of this key can be altered to provide a slow
display update (long integration time) for weighing in the presence of vibration. Follow
the procedure below to change the functionality of the int key to either a slow or a rapid
display update:
1. Press the key.
2. Enter 11110. This is the INT mode selection access code.
3. Press the cal key. The display will read “INT 1 or 0”.
4. Press 1 for a long integration time (vibration) or press 0 for a short integration
time (filling).
5. Press the cal key.
NOTE: The integration speed selected will remain programmed even if the scale
is off.
FORMATTING BAUD RATE
Your Setra balance is capable of interfacing with a wide variety of computer equipment
or other peripheral devices. To set the baud rate (the rate at which your balance sends
information to a computer or printer), use the following procedure:
1. Press the key.
2. Enter 5555. This is the baud rate access code.
3. Press the cal key. The display will read “cal br”.
4. Enter the baud rate. Choose either 300, 600, 1200, 2400, 4800 or 9600.
5. Press the cal key.
6. To retain this baud rate after power has been removed, repeat Steps 1-5 above
using the same baud rate.
NOTE: A baud rate of 2400 is automatically assigned when none is formatted.